Custom Query (337 matches)
Results (19 - 21 of 337)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#8 | implemented | Implement the existing checks for mistakes | ||
#9 | implemented | QNH setting should be logged with its original time and altitude | ||
Description |
QNH setting is logged when 10 seconds elapsed after the first change. However, it should be changed as follows: the change should be logged 10 seconds after the first change or 5 seconds after the last one, whichever comes first. The time and the altitude for the last change should be noted, and logged. |
|||
#11 | implemented | Implement the validation of FSUIPC data | ||
Description |
Since FSUIPC may be unreliable, implement the validation of data queried from it. If validation fails, we should immediately retry at most a fixed number of times and then fail the connection to reconnect. |